Operation and Maintenance Instructions:

Application:
The Time Delay “OFF” Controller operates as a single output controller where the application requires restrictive activation of a utility with a delay “OFF” after first activation.

This unit is ideally suited for shower units in correctional facilities or drug testing facilities where operation or use of the showers or lavatory facilities is to be limited to specific time periods, where operation “ON” can be established by authority.  Style 44’s use includes wash-down systems where predetermined cycled operation is required but with capabilities of short cycle activation on demand.

The delay “OFF” relays are housed in a remotely located enclosure with screw-on cover.  The active “ON” switching incorporates a momentary key-switch for Operation and a push-button “STOP” switch for immediate deactivation and are mounted on a stainless steel wall plate.

Time Delay “OFF” Settings:

Primary Operation  Styles 41 and 42

The unit has been factory set to operate for 2.5 hrs. upon activation.  The time delay relay may be set for any interval between 0 and 3 hrs. 

Short Cycle Operation   Styles 42; 43 and 44

The ISIMET Pulse Relay Operator is pre-set for a twenty (20) minute shorten cycle of operation for Style 42, five (5) minute for Style 43 and ten (10) minute for style 44.  The adjustment knob on the printed circuit board may be adjusted for slight desired variations in factory time settings.

Time Clock Operation   Style 44

An Electromechanical 24-hr Timer incorporated into the unit permits the user to program specific times of operation while permitting short cycle operation via the START button. Unit can be provided with the Start push button in lieu of the Key operating switch.